Capteur de courant DCCT 
et accessoires
 

 

 

Turnkey desktop and rack-mount system designed to measure and calibrate with high accuracy and high precision DC and AC currents up to ±1.000 A

CT-BOX
Current Transducer BOX 
Digital Current Measuring System

CT PCB Series
13 A, 26 A and 52 A PCB-Mount DC Current Transducers (DCCT)

 

 

±13 A, ±26 A and ±52 A high-precision DCCT series with current- or voltage-output versions

 

Closed-loop current transformer technology allows accurate monitoring of DC and AC bipolar currents up to ±52A with a small PCB-mount device. 

 

Galvanic isolaJon between primary and secondary conductor for simple current sensing at different potenJal. 

 

Standard current output and voltage output (“V”-version) available.

CT-100 / CT-150
100 A DC and 150 A DC Current Transducers (DCCT)

 

 

±100 A and ±150 A Full-Scale high precision DCCT's based on the 0-FLUCS technology available in the current-output or voltage-output version

 

Closed-loop current transformer technology allows accurate monitoring of DC and AC bipolar currents up to ±100A (CT-100) or up to ±150A (CT-150).

 

Galvanic isolaJon between primary and secondary conductor for simple current sensing at different potential. 

 

Standard current output and voltage output (“V”-version) available.

CT-200 / CT-300 / CT-400
200 A DC / 300 A DC / 400 A DC Current Transducers (DCCT)

 

 

±200 A /  ±300 A / ±400 A Full-Scale high precision DCCT based on the 0-FLUCS technology available in the current-output or voltage-output version

 

Closed-loop current transformer technology allows accurate monitoring of DC and AC
bipolar currents up to ±200A (CT-200), ±300A (CT-300) or ±400A (CT-400).


Galvanic isolation between primary and secondary conductor for simple current sensing at
different potential.


Standard current output and voltage output (“V”-version) available.

CT-600 / CT-1000
600 A DC and 1000 A DC Current Transducers (DCCT)

 

 

±600 A Full-Scale high precision DCCT based on the 0-FLUCS technology available in the current-output or voltage-output version

 

Closed-loop current transformer technology allows accurate monitoring of DC and AC
bipolar currents up to ±600A (CT-600) and to ±1000A (CT-1000).
 

Galvanic isolation between primary and secondary conductor for simple current sensing at
different potential.
 

Standard current output and voltage output (“V”-version) available.

Logo Faster Lab

Copyright FASTER LAB © . Tous droits réservés.

+33 (0)7 52 04 22 64                            contact@fasterlab.fr                          https://www.fasterlab.fr

Nous avons besoin de votre consentement pour charger les traductions